Solar Radiation Metal Halide Xenon Aging Test Chamber UV IEC 60068-2-5

Brand Name : Sinuo

Model Number : SN8816

Certification : Calibration Certificate (Cost Additional)

Place of Origin : China

MOQ : 1

Payment Terms : T/T

Delivery Time : 60 days

Supply Ability : 10 sets/month

Packaging Details : Plywood case

Price : Customized

Applied standard : IEC60068-2-5, MIL-STD810D, etc.

Light source : Metal halide lamp

Lamp power : 4KW

Lamp lifetime : About 500 hours

Total irradiance : 1120 W/m2±10% W/m2

Filter type : Sunlight filter

Chamber Temperature range : RT+10~70℃

Water Spray Cycle : 18min/102min

Contact Now

IEC 60068-2-5 Solar Radiation Metal Halide Lamp Aging Test Chamber

Complied Standards & Clauses


The Solar Radiation Test Chamber is designed and manufactured according to the standard requirement of IEC60068-2-5:2010, MIL-STD-810, DIN 75220 and etc.

Equipment Overview


The test chamber is mainly used to test the aging of automobiles, coatings, rubber, plastics, pigments, adhesives chemicals, fabrics, aerospace, naval vessels, electronics industry, packaging industry, and etc. by exposing the material sample to the light and heat radiation of the metal halide lamp.

It stimulates the full sunlight spectrum of halide lamp to reproduce the destructive light waves under different environment, which focuses on accelerating the photochemical effect of solar radiation. It can be used to detect the impact of long-term solar radiation on equipment, which can provide corresponding environmental simulations and accelerated tests for scientific research, product development and quality control.

This equipment can be used to select new materials, change existing materials, or evaluate changes in durability after changes in material composition. It can well simulate changes in materials exposed to sunlight under different environmental conditions.

Technical Parameters


Internal chamber size

1000×1000×1000mm(W*D*H)

Or can be customized

External chamber size Approx. 1620×1600×2250mm(W*D*H) subject to actual size
Spectral energy distribution Spectral range

Ultraviolet

rays A

Ultraviolet

rays B

Visible light Infrared Total radiation
Wavelength range 300-320nm 320-400nm 400-800nm 800-2450nm 300-2450nm
Radioactivity 4.06W/ m2 70.5W/ m2 604.2 W/ m2 186W/ m2 1090W/ m2
Percentage 0.4% 604% 55.4% 3708% 100%
Number of tubes Metal halide lamp: 1PC; Power: 4KW
Total irradiance 280~3000nm; 1120 W/m2±10% W/m2
Lamp lifetime About 500 hours
Filter type Sunlight filter
Internal chamber temperature range RT+10~70℃
Temperature heating/cooling rate Heating or cooling at a rate of 1℃/min
Black standard temperature range 40℃~100℃, adjustable(light cycle);25~85℃(dark cycle)
Thermometer Black standard thermometer BST
Temperature accuracy ±0.1℃
Temperature fluctuation ±0.5℃
Temperature variation ±3℃
Humidity range 30%~98%RH (in light off); 20%~60%RH(in light on)
Humidity accuracy ±1%RH
Humidity fluctuation ±3%RH
Humidity variation ≤±5%RH
Photoperiod time 1S~999H59M59S, continuous photoperiod time can be adjustable
Rainfall time 1S~9999min, continuous rainfall time can be adjustable
Rainfall cycle 1~240min interval (off) rainfall cycle time can be adjustable
Water spray cycle 18min/102min or 12min/48min (water spray time/non-water spray time)
Spray pressure 0.12~0.15Mpa
Nozzle aperture Ф0.8mm
Door sealant Silicone rubber tight sealing device
Sample holder material SUS304 stainless steel
Internal chamber material SUS304 stainless steel
External chamber material Cold rolled plate with stoving vanish
Protection System Over-temperature protection, leakage, short-circuit, phase-loss protection, buzzer alert when the test time is up
Environmental conditions Temperature 5℃~28℃; relative temperature ≤85%RH; atmospheric pressure 86kPa~106kPa
Power supply AC380V±10% (three-phase five-wire, make a 63A air switch separately, the air switch must have wiring terminals, and the power cord must be more than 6 square meters; 50±10%; 16KW).

Product Tags:

IEC xenon aging test chamber

      

automobiles xenon aging test chamber

      

IEC 60068-2-5 uv aging chamber

      
 Solar Radiation Metal Halide Xenon Aging Test Chamber UV IEC 60068-2-5 Manufactures

Solar Radiation Metal Halide Xenon Aging Test Chamber UV IEC 60068-2-5 Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Sinuo Testing Equipment Co. , Limited
*Subject:
*Message:
Characters Remaining: (0/3000)